Medical Equipment / Semiconductor Equipment Parts / Aerospace Parts/ ODM / OEM

Thumb

Sterile urinary catheter(Three chambers)


Sterile silicone lubricated ureter

.Silicone is one of four materials that the WHO determines can be permanently left in the body.
.Medical silicone has good biocompatibility, soft material, no irritation to patients, no allergic reaction.
.The inner diameter of the silicone ureter is wide, the inner cavity will not form calcium, precipitation, but lead to uneven drainage, leading to the problem of plucking.
.Suitable for medium and long-term urinary retention in the human body, the most common retention time is 28 days, can avoid multiple intubation, reduce the patient's pain and reduce the occurrence of cross-infection urinary tract.


Sterile silicone catheter Specifications: (Model/Diameter Size/Balloon Capacity/Total Length)

.WD-001-06 Two Way(2-WAY) 6Ch/Fr 1.5ml 300mm
.WD-001-08 Two Way (2-WAY) 8Ch/Fr 3ml 300mm
.WD-001-10 Two Way (2-WAY) 10Ch/Fr 3ml/3-5ml 300mm
.WD-001-12 Two Way (2-WAY) 12Ch/Fr 5ml/5-10ml 400mm
.WD-001-14 Two Way (2-WAY) 14Ch/Fr 5ml/5-10ml /15ml 400mm
.WD-001-16 Two Way (2-WAY) 16Ch/Fr 5ml/5-10ml /20ml/30ml 400mm
.WD-001-18 Two Way (2-WAY) 18Ch/Fr 5ml/5-10ml /20ml/30ml 400mm
.WD-001-20 Two Way (2-WAY) 20Ch/Fr 10ml/30ml 400mm
.WD-001-22 Two Way (2-WAY) 22Ch/Fr 10ml/30ml 400mm
.WD-001-24 Two Way (2-WAY) 24Ch/Fr 10ml/30ml 400mm
.WD-001-26 Two Way (2-WAY) 26Ch/Fr 10ml/30ml 400mm
.WD-002-14 Three Way(3-WAY) 14Ch/Fr 5ml/5-10ml /15ml 400mm
.WD-002-16 Three Way (3-WAY) 16Ch/Fr 5ml/5-10ml /20ml/30ml 400mm
.WD-002-18 Three Way (3-WAY) 18Ch/Fr 5ml/5-10ml /20ml/30ml 400mm
.WD-002-20 Three Way (3-WAY) 20Ch/Fr 10ml/30ml 400mm
.WD-002-22 Three Way (3-WAY) 22Ch/Fr 10ml/30ml 400mm
.WD-002-24 Three Way (3-WAY) 24Ch/Fr 10ml/30ml 400mm
.WD-002-26 Three Way (3-WAY) 26Ch/Fr 10ml/30ml 400mm

Note:
1.This product is sterilized with ethylene oxide (EO)
2.This product must be operated by a paramedic or professionally trained person
3.This product is a single-use product, after use can not be sterilized again reuse
4.Do not use sharp objects to operate this product, so as not to break this product
5.Silicone catheter continuous tube should not exceed 29 days. New tube replacement recommended for 2 ~ 4 weeks based on health considerations
6.Should be stored in a dry and cool environment, this product is valid for: 3 years                                                                                                                     








DOWNLOAD: